General
The project brief was to improve the tanker imports to the site. Process selection was chosen in order to utilise the Anglian water framework for sludge screening.
Design Basis
This project was designed in order to provide a reception tank to act as a buffer for both imports and indigenous sludge and then pump it via dedicated duty/assist pumps and sludge screens to an existing Picket Fence Thickener.The thickened sludge pumps were replaced to accommodate the increased throughput.
A new kiosk with MCC was provided for the plant controls and instrumentation.